Parametric control
Every family includes type parameters for module width, storey height, glass thickness, thermal break configuration and finish color. Instance parameters control panel-specific details like opening sizes, corner angles and setback depths.
LOD 300–400 geometry
Models include fabrication-level detail: mullion profiles with drainage channels, transom connections, thermal break geometry, gasket grooves and fastening points. Suitable for clash detection, quantity takeoff and fabrication drawings.
Thermal performance data
Each family carries thermal properties: U-value, SHGC, VLT and air permeability ratings. Data is tied to the glass configuration parameter so schedules automatically update when glazing changes.