Each panel is built in the factory from four layers of engineering: the aluminum support frame (mullions and transoms with thermal-break profiles where required), the infill (insulating glass, spandrel or louvre), the two-stage weather seal, and the inter-panel gasketing that creates the rain screen.
The defining detail is the vertical and horizontal interface: adjacent units interlock through a pressure-equalized cavity with an outer weather seal and an inner air seal. Rain never crosses the cavity because the outer seal sheds it and the cavity is vented to equalize pressure — the same principle used in rain screen systems worldwide.
Because the panel is completed and tested horizontally on the factory floor, the variables that ruin stick-built quality — site humidity during sealant application, inconsistent joint preparation, weather interruptions — are removed from the critical path.