Curtain Wall Standards Hub

The codes that govern curtain wall performance — air, water, structural, thermal and fire — in one quick-reference table: scope, regions, key values and how each relates to the Chinese framework your team may already know.

ASTM / AAMA EN 13830 Family BS EN 13830 GB/T 21086 & JGJ 102
How to Use This Hub

Six Questions, Many Codes

Every curtain wall standard on earth asks the same six questions: How much air leaks? How much water gets in under wind? What wind load can it take? How does it behave under building drift? How much heat passes? How does it perform in fire? The codes below differ in method, units, class boundaries and legal force — not in the questions. Find your project's jurisdiction, read the scope, then verify the exact class or pressure against your specification.

The full explainer with test-report reading method lives on the Global Facade Standards guide; the hub below is the index. For fire-specific ratings, see the Fire-Rated Glass & Curtain Wall Ratings matrix.

Master Table

Curtain Wall Standards at a Glance

StandardRegionWhat It CoversKey Values / ClassesRelation to Chinese Framework
GB/T 21086ChinaPerformance grading of curtain wallsAir 1–4, water 1–5, wind 1–9Base performance standard
JGJ 102ChinaGlass curtain wall engineering practiceDesign, materials, acceptanceEngineering code for GB/T 21086
GB 50009ChinaStructural loads (incl. wind load)Design wind pressure by regionFeeds wind load into facade design
ASTM E283USAAir leakage test methodReported as m³/h·m² at pressureMethod equivalent to GB/T 7106 family
ASTM E330USAStructural wind load testTested at 1.5 × design, L/240 maxMethod equivalent to GB/T 15227
ASTM E331USAStatic water penetration testNo leakage at stated pressureMethod equivalent to GB/T 15227 water
AAMA 501.1USAField water test of installed facadeField test protocolCounterpart: on-site inspection per JGJ 102
AAMA 501.4USAInter-storey drift testDrift capability verificationCounterpart: GB/T 29043 drift tests
AAMA 501.5USAThermal cycling of fenestrationCycling protocolLess common in CN practice
AAMA 2604USAHigh-performance organic coatingsCoating performance classesCounterpart: GB/T 5237.5
AAMA 2605USASuperior PVDF coatings (20 yr)Strictest coating classCounterpart: GB/T 5237.5 high class
EN 13830EuropeProduct standard for curtain wallingAir AE classes, water RE classesFramework counterpart of GB/T 21086
EN 12152/12153EuropeAir permeability classification/testAE 0 best .. AE 1350Counterpart: GB/T 21086 air classes
EN 12154/12155EuropeWatertightness classification/testRE 1.5 kPa upwardCounterpart: GB/T water classes
EN 13116EuropeWind resistance testClasses up to 5 × pressureCounterpart: GB/T wind classes
BS EN 13830United KingdomUK-adopted EN 13830 (CE marking)Same classes; CE legal routeSee dedicated comparison below
CWCTUK / Middle EastSystemised building envelopes, performanceAir/water/structural/thermal/fire/E MCPerformance standard; often on top of EN
ETAG 002EuropeStructural sealant glazing (SSG)SSG system requirementsFeeds SSG design practice worldwide
ISO 10077-2InternationalThermal U-value of framesFrame U-value calcUsed inside CN thermal design too
EN 1364-3EuropeFire resistance of curtain wallingE/EI 30–120 ratingsCounterpart: GB/T 29467 / JGJ fire rules

Reading note: "Counterpart" means the Chinese system covers the same performance question with its own method — class numbers and pressures do not map one-to-one between frameworks. Always read the tested pressure/class, the code and the acceptance criteria together. The comparison table below illustrates the two most common translation pairs.

Focus

BS EN 13830 — The UK Product Standard

BS EN 13830 is the British adoption of the European product standard for curtain walling, harmonised under the Construction Products Regulation (EU 305/2011). For UK and many international projects it is the legal route to market: curtain walling kits carry CE marking (and UKCA for the GB market) based on system-level assessment to EN 13830, supported by the EN test-method family — EN 12152/12153 (air), EN 12154/12155 (water), EN 13116 (wind), EN 13119 (terms), with thermal performance per ISO 10077-2 and EN ISO 12631.

Performance is expressed in class systems, not single numbers: air permeability from AE 1350 (loosest) to AE 0 (tightest), watertightness from RE 1.5 kPa upward in 0.5–1.0 kPa steps, and wind resistance classes verified at increasing test pressures. On UK towers, CWCT testing (performance-based) is frequently added on top of EN 13830 certification, with the most onerous requirement prevailing.

AspectBS EN 13830 (UK / Europe)GB/T 21086 & JGJ 102 (China)
NatureHarmonised product standard — CE/UKCA route for kitsPerformance grading + engineering practice code
Air permeabilityClasses AE 1350 → AE 0 (lower = better)Classes 1–4 (higher = better)
WatertightnessRE 1.5 kPa+ class stepsClasses 1–5 (fixed), 1–3 (operable)
Wind loadPressure classes, verified to 5 × design in family testsClasses 1–9 by P3 test pressure
Legal forceCE/UKCA required for market accessJGJ 102 mandatory for domestic acceptance
ThermalISO 10077-2 / EN ISO 12631 U-valuesGB 50176 / JGJ 102 thermal requirements
FireEN 1364-3 (E/EI ratings)GB/T 29467 + national fire rules

The practical takeaway for international projects: choose one primary code, then verify the numbers, not the names. Hanart routinely engineers to both frameworks and documents each performance class with independent test evidence — see the full standards guide for how to read and compare test reports.

Compliance

How Hanart documents code compliance

For every export project Hanart issues a compliance matrix that maps each relevant standard clause to the engineering response: calculation method, test standard, component certificate or inspection record. This is prepared at design stage, not at handover, so gaps surface while they are still cheap to close.

Test evidence comes from three levels: accredited laboratory reports (air, water, structural and thermal), in-plant seal and dimensional inspection records, and site verification including watertightness testing before handover. The combination covers the standard, the product and the installation.

  • Standard-by-standard scope and key values, as in the tables above
  • Clause-level compliance matrix for the project jurisdiction
  • Laboratory, in-plant and site test evidence in one dossier
  • BS EN 13830, EN 13830, ASTM, AAMA, CWCT, GB/T 21086 and JGJ 102 mapping
Documentation

Typical documentation we hand over

Each project closes with a standards-aligned dossier: compliance matrix, calculations, laboratory and in-plant test records, site watertightness verification, as-built drawings and a maintenance manual. For UK projects the BS EN 13830 classification summary and CE / UKCA documentation are included as part of the handover set.