Stick-Built Curtain Wall Technical Downloads

Complete technical documentation for Hanart stick-built curtain wall systems — structural framing profiles, expansion joint details, field installation manuals, and quality control procedures.

System Overview

Stick-Built Curtain Wall System

Hanart stick-built curtain wall systems are assembled piece-by-piece on site: mullions first, then transoms, then glazing. This versatile system offers maximum design flexibility, cost efficiency, and is ideal for mid-rise buildings, renovations, and projects with complex geometry.

Design Flexibility

Stick-built systems adapt to any building geometry — slopes, corners, curves, and complex intersections. Components are cut to length during fabrication, so special conditions are easy to accommodate.

Cost-Effective

Without the factory tooling and logistics of unitized panels, stick-built systems offer the lowest cost per square meter among curtain wall types. Ideal for buildings up to 15–20 stories.

Field-Proven Installation

Our documentation supports efficient on-site assembly: sequenced installation guides, weatherproofing best practices, and quality control procedures developed across 30 years of field experience.

Technical Documents

Download Library

Document Format Size Description Download
System Specification — Stick-Built Curtain Wall PDF 2.6 MB Complete system specification: framing profiles, glazing, gaskets, anchors, and expansion provisions. 45 pages. Request Download
Standard Details — Sections, Junctions & Anchors DWG / PDF 6.8 MB Typical vertical and horizontal sections, mullion splice details, expansion joints, anchor configurations, and interface details for all building conditions. AutoCAD 2018 compatible. Request Download
Revit Family — Mullion & Transom Profile RFA 2.4 MB Parametric family set: mullion, transom, and connection elements with profile geometry and material properties. Revit 2020–2026 compatible. Request Download
Expansion Joint Detail Package DWG / PDF 2.9 MB Detailed expansion joint solutions: vertical and horizontal movement accommodation up to 25mm, weatherseal configurations, and insulation continuity details. Request Download
Field Installation Manual PDF 9.3 MB Complete field installation guide: layout, anchor setting, mullion plumb and alignment, transom installation, glazing, and joint sealing. 88 pages with progressive photo documentation. Request Download
Quality Control Procedures PDF 2.1 MB Site QC procedures: alignment tolerance verification, anchor embedment checks, water test protocols, and documentation forms for each installation stage. Request Download
Weatherproofing Best Practices PDF 1.5 MB Prevention and remediation of water intrusion: sealant joint design, drainage paths, backer rod selection, and weep system verification. Request Download
Glazing & Gasket Application Guide PDF 1.8 MB Glazing pocket sizing, setting blocks, gasket selection and installation for stick-built systems, including torsion, structural, and wedge gasket configurations. Request Download
Maintenance Manual PDF 1.4 MB Periodic maintenance: gasket replacement, sealant renewal, hardware lubrication, and inspection intervals for stick-built curtain walls. Request Download
Tested Performance

Standard Performance Characteristics

Third-party tested performance data for Hanart stick-built curtain wall systems (standard configuration).

Performance Parameter Test Standard Result Rating
Air Infiltration ASTM E283 0.06 cfm/ft² @ 6.24 psf Class AW (AAMA 501.4)
Water Penetration ASTM E331 Zero penetration @ 15 psf (720 Pa) Pass
Structural Load ASTM E330 No deflection > L/175 @ 5,000 Pa Pass
Thermal Transmittance (with 24mm IGU) NFRC 100 / ISO 10211 U-value 1.1–1.6 W/m²K High Performance
Thermal Break Performance AAMA 505 Polyamide break 34mm — condensing resistance CRF 58+ High Performance
Acoustic Performance ASTM E90 / ISO 140-3 STC 32–40 Standard to High
Inter-story Drift Accommodation AAMA 501.1 Up to ±15mm mirrored movement Verified
Technical Questions

Frequently Asked Questions

When should I choose a stick-built system over unitized?

Choose stick-built for: (1) buildings up to 15–20 stories, (2) budget-sensitive projects, (3) complex geometry that requires custom field solutions, (4) sites without crane access for panel lifting, and (5) renovation projects where unitized panels cannot be maneuvered. Above 20 stories, unitized systems usually become more cost-effective due to installation speed.

What installation tolerances do you guarantee?

We guarantee: mullion plumb ±3mm per 3m, surface alignment ±3mm, anchor position ±10mm with adjustment allowance, and glazing pocket clearances per system specification. Our QC procedures document each verification with field checklists.

How do you handle thermal expansion in long facades?

We incorporate expansion joints at intervals determined by thermal analysis — typically every 15–25 meters depending on profile material, temperature range, and facade orientation. Our expansion joint detail package includes complete solutions for vertical and horizontal movement.

Can stick-built systems achieve the same performance as unitized systems?

Yes — with careful detailing, stick-built systems achieve the same air, water, and structural performance classes. The main trade-offs are installation speed (2–3× slower) and more field labor, not performance. Field QC rigor is the key success factor, which is why we provide comprehensive installation and QC documentation.

Do you supply the profiles or just engineering?

We supply complete systems: extruded aluminum profiles, gaskets, hardware, anchors, fabricated components, and all installation materials. We also support with on-site technical supervision for critical installation stages — anchor setting, first mullion plaza, and water testing.

Need Project-Specific Technical Support?

Our engineering team provides project-specific stick-built system design, shop drawings, and installation supervision. Contact us for technical support or quotation.