Structural Silicone Glazing Technical Downloads

Complete technical documentation for Hanart structural silicone glazing (SSG) systems — detail libraries, silicone joint specifications, weatherseal application guides, and factory quality inspection checklists.

System Overview

Structural Silicone Glazing System

Hanart structural silicone glazing (SSG) bonds glass directly to the aluminum frame with high-strength structural silicone, eliminating visible caps and creating a smooth, seamless facade surface. Ideal for modern curtain wall and storefront designs.

Seamless Glass Surface

Glass is structurally bonded to the frame, leaving no exterior pressure plates or caps. The result is a smooth, flush glass surface with uninterrupted sightlines — a signature of modern commercial architecture.

Factory or Field Glazed

SSG units can be structurally glazed in our factory under controlled temperature and humidity, or field-glazed with weather-shielded procedures for retrofit projects. Both methods follow ASTM C1401 quality protocols.

Proven Longevity

With properly designed joints and accredited silicone systems, structural glazing has a 40+ year service history. Our design criteria follow ASTM C1401 and EBST guidelines with a minimum 10x design safety factor on silicone bite.

Technical Documents

Download Library

Document Format Size Description Download
SSG Detail Library — Complete Set DWG / PDF 6.3 MB Comprehensive SSG details: head, sill, jamb, horizontal and vertical expansion joints, corner conditions, and interface details. AutoCAD 2018 compatible. Request Download
System Specification — Structural Silicone Glazing PDF 2.2 MB Complete system specification: silicone selection, joint dimensions, structural bite, gaskets, and frame requirements. 38 pages. Request Download
Structural Silicone Joint Design Guide PDF 1.6 MB Design methodology for structural silicone joints: bite depth calculation, wind load capacity, temperature movement, and seismic displacement. Includes worked examples per ASTM C1401. Request Download
Revit Family — SSG Spandrel Panel RFA 2.0 MB Parametric SSG spandrel panel family with silicone joint parameters visible in 3D. Revit 2020–2026 compatible. Request Download
Glazing Rebate Specification Table XLSX / PDF 0.7 MB Editable glazing rebate specification table: bite depth, joint width, silicone type, and adhesion testing requirements for various glass and frame combinations. Request Download
Weatherseal Application Guide PDF 2.4 MB Field application guide for weatherseals: surface preparation, primer requirements, application temperature ranges, tooling techniques, and cure time verification. Request Download
Factory & Field Quality Inspection Checklist PDF 0.9 MB Certification-ready inspection checklists: adhesion testing, peel testing, tensile testing, joint geometry verification, and documentation requirements. Request Download
Silicone Adhesion Test Protocol PDF 1.3 MB Adhesion testing protocol per ASTM C1521: surface preparation, test sample preparation, curing conditions, and acceptance criteria for adhesion failures. Request Download
Maintenance Manual — SSG Facades PDF 1.5 MB Periodic inspection schedule, sealant condition assessment, repair procedures, and lifecycle guidance for structurally glazed facades. Request Download
Tested Performance

Standard Performance Characteristics

Third-party tested and certified performance data for Hanart structural silicone glazing systems.

Performance Parameter Test Standard Result Rating
Air Infiltration ASTM E283 0.05 cfm/ft² @ 6.24 psf Class AW (AAMA 501.4)
Water Penetration ASTM E331 Zero penetration @ 15 psf (720 Pa) Pass
Structural Load ASTM E330 No deflection > L/175 @ 5,000 Pa Pass
Silicone Joint Design Safety Factor ASTM C1401 Minimum 10x on silicone bite capacity Exceeds Standard
Silicone Adhesion Strength ASTM C1135 ≥ 50 psi (345 kPa) tested adhesion Pass
Thermal Transmittance (with 24mm IGU) NFRC 100 / ISO 10211 U-value 1.1–1.5 W/m²K High Performance
Acoustic Performance ASTM E90 / ISO 140-3 STC 33–39 Standard to High
Technical Questions

Frequently Asked Questions

What silicone types do you use for structural glazing?

We use accredited structural silicone systems from Dow, Sika, and other global manufacturers, all tested for adhesion to our specific glass coatings and aluminum finishes. The chosen system depends on your project's load requirements, climate, and substrate combination — we specify it in the project engineering package.

What is the required silicone bite depth?

Bite depth is calculated per ASTM C1401 based on wind load, glass panel dimensions, and joint requirements. Typical bite depths range from 6mm to 12mm. Our joint design guide includes calculation worksheets for your specific conditions.

Is field glazing possible, or is factory glazing required?

Both are possible. Factory glazing is recommended for optimal quality control and speed. Field glazing is feasible for retrofit projects and uses a more complex weather-shielded procedure with additional adhesion testing. Our inspection checklists support both workflows.

How do you verify silicone adhesion quality on a real project?

We follow ASTM C1521 adhesion testing protocols on project samples — peel tests at regular intervals during production, plus pull-tab tests on actual production joints. Test cards are documented with photos and logged into the project quality file, available to the client and third-party inspectors.

Can SSG be combined with unitized panel production?

Yes — unitized SSG combines the quality and speed of factory production with the seamless appearance of structural glazing. Panels are structurally glazed on our production line, then installed like standard unitized panels. This is one of Hanart's most requested configurations for premium commercial towers.

Need Project-Specific Technical Support?

Our engineering team provides project-specific silicone joint designs, adhesion test protocols, and BIM coordination for structural glazing projects. Contact us for design assistance, value engineering, or installation planning.