Unitized Curtain Wall Technical Downloads

Complete technical documentation for Hanart unitized curtain wall systems — DWG details, Revit families, specifications, performance data, and installation guides.

System Overview

Unitized Curtain Wall System

Hanart's unitized curtain wall system delivers factory-finished panels that minimize on-site work, accelerate installation schedules, and ensure consistent quality. Panels are pre-glazed, pre-gasketed, and pre-finished before shipping to site.

Factory Quality Control

Every panel undergoes 100% visual inspection, air infiltration testing, and dimensional verification before leaving our Qingpu facility. Quality consistency that field-assembled systems cannot match.

Rapid Installation

Unitized panels install at 8–12 panels per crew per day — 3–4× faster than stick-built systems. Weather-independent installation with minimal scaffolding requirements.

Thermal Performance

Polyamide thermal break technology achieves U-values of 1.0–1.4 W/m²K with double glazing, and 0.7–0.9 W/m²K with triple glazing options. Pressure-equalized rainscreen design eliminates water penetration.

Technical Documents

Download Library

Document Format Size Description Download
System Specification — Unitized Curtain Wall PDF 2.4 MB Complete system specification: profiles, glazing, gaskets, anchors, thermal breaks, and finishes. 48 pages. Request Download
Standard Details — Sections & Elevations DWG / PDF 5.1 MB Typical vertical and horizontal sections, stack joint detail, corner condition, parapet condition, and ground floor condition. AutoCAD 2018 compatible. Request Download
Revit Family — Unitized Panel (Standard) RFA 3.8 MB Parametric Revit family for 1200mm and 1500mm module widths. Includes thermal break geometry, glazing options, and anchor families. Revit 2020–2026 compatible. Request Download
Revit Family — Unitized Panel (Custom Module) RFA 4.2 MB Flexible parametric family with adjustable module width (600–2400mm), glazing thickness, and thermal break depth. Revit 2020–2026 compatible. Request Download
Performance Data Sheet PDF 1.1 MB Tested performance data: air infiltration (ASTM E283), water penetration (ASTM E331), structural load (ASTM E330), thermal transmittance (NFRC 100), and acoustic performance (ASTM E90). Request Download
Installation Manual PDF 8.5 MB Step-by-step installation guide: crane logistics, panel sequencing, anchor installation, weatherseal application, and quality inspection checklists. 72 pages with illustrations. Request Download
Anchor & Connection Details DWG / PDF 3.2 MB Structural connection details: bracket types, anchor bolts, embed plates, seismic connectors, and dead-load / live-load distribution diagrams. Request Download
Glazing Schedule Template XLSX / PDF 0.8 MB Editable glazing schedule template with Hanart standard glass types: clear tempered, low-e, laminated, acoustic, and fire-rated options with performance properties. Request Download
BIM Content Guide PDF 1.5 MB Guide to using Hanart BIM content: family parameters, LOD recommendations, material mapping, and coordination workflows with structural and MEP models. Request Download
Maintenance & Warranty Manual PDF 2.0 MB Recommended maintenance schedule, inspection protocols, gasket replacement procedures, and 10-year warranty terms and conditions. Request Download
Tested Performance

Standard Performance Characteristics

Third-party tested and certified performance data for Hanart unitized curtain wall systems.

Performance Parameter Test Standard Result Rating
Air Infiltration ASTM E283 0.06 cfm/ft² @ 6.24 psf Class AW (AAMA 501.4)
Water Penetration ASTM E331 Zero penetration @ 15 psf (720 Pa) Pass
Structural Load ASTM E330 No deflection > L/175 @ 5,000 Pa Pass
Thermal Transmittance (Double Glazing) NFRC 100 / ISO 10211 U-value 1.0–1.4 W/m²K High Performance
Thermal Transmittance (Triple Glazing) NFRC 100 / ISO 10211 U-value 0.7–0.9 W/m²K Ultra-High Performance
Acoustic Performance ASTM E90 / ISO 140-3 STC 32–38 (double) / STC 38–44 (triple) Standard to High
Condensation Resistance AAMA 1503 CRF 62 (frame) / CRF 72 (glass center) Excellent
Seismic Performance ICC-ES AC156 Passed at Sds 1.5g, Ip 1.5 Seismic Verified
Technical Questions

Frequently Asked Questions

What Revit versions are your families compatible with?

Hanart Revit families are developed and tested for Revit 2020, 2021, 2022, 2023, 2024, 2025, and 2026. Backward compatibility to Revit 2019 is available on request. All families use shared parameters for consistent scheduling and tagging across versions.

Can I use your DWG details in my tender documents?

Yes — Hanart technical drawings are free to use for design development, tendering, and contractor pre-qualification. They are indicative system content showing typical configurations. Final shop drawings, project-specific profiles, and performance guarantees are issued with your formal quotation and engineering package.

Do you provide custom module sizes?

Absolutely. While our standard families cover 1200mm and 1500mm modules (the most common sizes), we fabricate unitized panels in custom dimensions from 600mm to 3000mm width. Contact us with your project module requirements and we will provide custom Revit families and shop drawings.

Are the performance values guaranteed for my project?

The performance data shown here represents third-party tested values for standard configurations. Project-specific performance guarantees are provided with formal quotations based on your exact glazing specification, module dimensions, wind loads, and thermal requirements. We can conduct project-specific testing if required by building codes or green certification programs.

How do I request a project-specific engineering package?

Submit an RFI through our quotation request form or contact us directly. Project-specific engineering packages include: shop drawings, structural calculations, thermal analysis, acoustic modeling, and installation sequencing — typically delivered within 10–15 working days of design brief confirmation.

Need Project-Specific Technical Support?

Our engineering team provides custom details, calculations, and BIM coordination for your specific project requirements. Contact us for design assistance, value engineering, or installation planning.